The lab calendar
- Checked
- 5 to 11 Nov 2026
- By
- John Cruz, RN
Which lab draws have an outside schedule, and which are the facility's choice.
| Line | What it says | Binds | Where it says so |
|---|---|---|---|
| Required | |||
| Albumin and weight monthly | Measure albumin and body weight for every patient. Clock: At least monthly, from admission, then each month. | Required | 42 CFR 494.90(a)(2) |
| Once it's in your policy | A house practice written into facility policy has to be followed: the medical director must ensure the policies on admissions, patient care, infection control and safety are adhered to. A surveyor reads your policy against your floor, even where no outside rule set the clock. | Required | 42 CFR 494.150(c)(2)(i) |
| EQRS submission | Furnish data to CMS electronically, at the intervals CMS specifies. Monthly clinical values go into EQRS. Clock: About 2 months after each reporting month, from the end of the reporting month. | Required | 42 CFR 494.180(h) |
| CMS guidance | |||
| Assessment lab work-up | The comprehensive assessment includes a laboratory work-up: comprehensive metabolic testing, adequacy, a complete blood count, iron studies and hepatitis B screening. The guidance names what to draw at assessment, not a monthly rhythm. Clock: At each comprehensive assessment, from admission (then each reassessment). | CMS guidance | Appendix H (Rev. 246), V505 |
| Professional guideline | |||
| HbA1c (KDIGO) | For patients with diabetes, HbA1c twice a year is reasonable, up to four times a year if the target isn't met or therapy changes. The guideline adds that HbA1c is less reliable in dialysis patients. Clock: Twice a year; up to 4 times, from a diabetes diagnosis. | Professional guideline | KDIGO Diabetes 2022, Practice Points 2.1.1 and 2.1.2 |
| Lipids (KDIGO) | Measure lipids at the initial evaluation. Follow-up measurement isn't required for most patients. Clock: Once, at initial evaluation, from the initial evaluation. | Professional guideline | KDIGO Lipids 2013, Recommendations 1.1 and 1.2 |
| House practice | |||
| Monthly chemistry panel | A monthly chemistry panel. No regulation, survey guidance or guideline sets a monthly clock for the panel itself. Clock: Monthly, by facility custom, from the facility's lab calendar. | House practice | No outside source |
| B12 and folate | A routine B12 and folate draw. The anemia and mineral guidelines read for this page set no calendar for it; when it's drawn is the facility's choice. | House practice | No outside source |
What this sheet can't tell you
- State rules and accrediting organization standards aren't covered.