V116 Items taken to the dialysis station
Written V0116 on the CMS-2567 and in QCOR.
Cited on this tag? What happens after a citation · One-page sheet for the binder
The regulation
CDC RR-05 as Adopted by Reference 42 CFR 494.30 (a)(1)(i)
Items taken into the dialysis station should either be disposed of, dedicated for use only on a single patient, or cleaned and disinfected before being taken to a common clean area or used on another patient.
- Non-disposable items that cannot be cleaned and disinfected (e.g., adhesive tape, cloth covered blood pressure cuffs) should be dedicated for use only on a single patient.
- Unused medications (including multiple dose vials containing diluents) or supplies (syringes, alcohol swabs, etc.) taken to the patient’s station should be used only for that patient and should not be returned to a common clean area or used on other patients.
CMS's interpretive guidance
Interpretive Guidance § 494.30(a)(1)(i)
According to the CDC, any item taken to a patient’s dialysis station could become contaminated with blood and other bodily fluids, serving as a vehicle of transmission to other patients either directly or through contamination from personnel's hands. Items taken to a patient’s dialysis station include those placed on the top or sides (in baskets) of dialysis machines and on dialysis chairs.
After use, all equipment and supplies must be considered potentially blood-contaminated and should be separated, handled with caution, and either disinfected or discarded. If provided, linens should be removed after use, separated from clean items, and laundered. If blood pressure cuffs are used for multiple patients, the coverings must be disposable or able to be adequately disinfected.
If the facility provides linens or blankets for patient use, these items should be considered potentially contaminated with blood. If patients bring their own blankets, pillows, etc., they should be instructed to wash the linen they bring to treatment and use bleach to remove blood stains.
If the facility provides portable or cellular phones, remote controls, or individual televisions for patient use during treatment, these items must be properly cleaned and disinfected before use by another patient.