V401 Safe, functional, comfortable environment

Written V0401 on the CMS-2567 and in QCOR.

Enforces 42 CFR 494.60 · Appendix H Rev. 246, page 186 · checked 12 Nov 2026

Cited on this tag? What happens after a citation · One-page sheet for the binder

The regulation

§494.60 - The dialysis facility must be designed, constructed, equipped, and maintained to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment.

Read 42 CFR 494.60 on the eCFR

CMS's interpretive guidance

Interpretive Guidance §494.60:

Safe environment means that there are no obstacles that would present risks for trips and falls, such as loose floor tiles; no areas that would pose infection control risks, such as broken work surfaces; and no outside doors that remain propped open, allowing entry of unauthorized individuals, insects, or animals, or creating a hazard in the event of fire.

Functional environment means that all systems in the building, such as lighting, heating, and air conditioning, are operational.

A comfortable environment includes providing sufficient space for patient privacy and access to necessary equipment, while also maintaining a reasonable noise level. For example, this may involve requiring the use of earphones when televisions or other entertainment devices are in use, as they can disturb others. Monitoring a comfortable temperature is addressed at V405.

Verbatim from Appendix H Rev. 246, with CMS's headings, lists and bold. Check page 186 (the full 469-page PDF) before quoting it.