V405 Comfortable temperature, with accommodations
Written V0405 on the CMS-2567 and in QCOR.
Cited on this tag? What happens after a citation · One-page sheet for the binder
The regulation
§ 494.60(c)(2) - The dialysis facility must:
(i) Maintain a comfortable temperature within the facility; and
(ii) Make reasonable accommodations for the patients who are not comfortable at this temperature.
CMS's interpretive guidance
Interpretive Guidance §494.60(c)(2)
The facility must make reasonable efforts to provide a comfortable environment for patients and staff, in spite of conflicting perceptions of “comfortable.”
It is not uncommon for patients to feel cold during their dialysis treatments, and there are many reasons that some patients experience feeling uncomfortable in the facility. Some reasons for feeling cold include:
- Anemia: many patients with chronic kidney disease do not produce enough red blood cells which circulate and carry oxygen throughout the body. This leads to patients feeling cold and tired;
- Skin exposure, if the patient has a graft or fistula;
- Remaining seated for 3-4 hours during treatment with limited ability to move around; and
- Blood temperature: during dialysis, blood is circulated outside of the body, sent through the dialyzer to filter wastes and toxins and then returned back to the patient which may lead to some patients feeling uncomfortable and cold.
Dialysis facility staff tend to experience more warmth than patients due to the PPE that is worn and staying active for extended periods of time to perform their duties, which may affect their perception of what constitutes a comfortable temperature. Dialysis facility staff should take measures to ensure temperatures within the facility are maintained at a comfortable level. Unlike operating rooms, which are required to maintain cooler air temperatures, dialysis facilities may use the standard temperature range of 70°F–75°F (21°C–24°C) to achieve a greater degree of patient and staff comfort (CDC guidance for Environmental Infection Control in Health-Care Facilities).
The dialysis facility must make attempts to address any causal factors that lead to a patient feeling uncomfortable with the room temperature set by the dialysis unit. For example, “reasonable accommodations” would include offering hats, blankets, or other warming devices. Patients that are seated near vents or windows may also experience feeling cold or uncomfortable and may need to be moved to another area of the room. When cold, some patients find it helpful to use a glove for the hand on their access arm, others find wearing a cap helpful.
§ 494.60(c)(4) requires the patient to be in view of staff during hemodialysis treatments to ensure patient safety. This includes direct visualization of their vascular access site to assess for patency and appropriate connections, e.g. central venous catheter site or an AV fistula/graft. If patients choose to use a blanket or other covering, their vascular access site, bloodline connections, and face must be visible throughout the treatment. A head covering on a patient is acceptable, as are gloves. If there are concerns for patient or vascular access site visualization during hemodialysis treatments, refer to V407.