V271 Chlorine breakthrough: holding tank water only if safe

Written V0271 on the CMS-2567 and in QCOR.

Enforces 42 CFR 494.40(b)(2)(ii)(B) · Appendix H Rev. 246, page 125 · checked 12 Nov 2026

Cited on this tag? What happens after a citation · One-page sheet for the binder

The regulation

§ 494.40(b)(2)(ii) - If the test results from the last component or carbon tank are greater than the parameters for chlorine or chloramine specified in paragraph (b)(2)(i) of this section the facility must—
(B) Only allow use of purified water in a holding tank, if appropriate, and if testing shows water chlorine or chloramine levels that are in compliance with paragraph (b)(2)(i) of this section; and

Read 42 CFR 494.40 on the eCFR

CMS's interpretive guidance

Interpretive Guidance § 494.40(b)(2)(ii)(B)

If the system includes a holding tank and the water in that tank tests safe for chlorine and chloramine, that water may be used for patient treatment. Responsible staff must know how to prevent the water treatment system from continuing to make product water, thus adding water containing unsafe levels of chlorine to the storage or holding tank. Water produced by exhausted carbon tanks must not be used for treatment.